  this is a 6-digit analog integrator which displays an inte- gral upon receiving fc series signals or signals from slide rheostat. features 1. accuracy of 0.5%. 2. a variety of integral levels are available for free choice, optimum for process lines. 3. the instrument permits transmitting pulses up to 10 times as many as the integral level selected. the integrator can easily be connected to a computer through a remote data transmission system. the output stage is prepared in three types for op- tional choice in accordance with practical require- ments. specifications measuring signal : fc series signal dc 1 to 5v dc 4 to 20ma wiring resistance : 5 ? or less per wire circuit resistance adjustment unneces sary (for slide rheostat) input resistance : 1m ? (dc 1 to 5v) 250 ? (dc 4 to 20ma) allowance : rated value means the theoretical value to be obtained when 100% input is continuously applied and integrated. display mode : decimal 6-digit electromagnetic counter (with click-touch reset pushbutton) integral level : value to be integrated for 1 hour at 100% input: 50 100 200 250 300 400 500 600 750 800 900 1000 1200 1500 1600 1800 2000 power supply : dc24v (20 to 30v or ac 100v 10%, 50/60 hz) power consumption: approx. 6w (dc 24v) approx. 9va (ac 100v) (including power consumption by pulse transmitter) power indicator lamp: rectangular green led ambient temperature: 0 to 45?c ambient humidity: 90% rh (max) enclosure : steel case external dimensions (hxwxd): 144 x 72 x 400 mm (casing) + terminal board mass (weight) : approx. 4.5kg finish color : munsell 7y 7.3/1.4 data sheet pke fc series integrator input 5 to 100% within 0.5%of rating within 1% of rating input less than 5% date EDS10-12E jan. 6, 2006
2 pke basic operating principle diagram integration cutoff : integration starts at 10% or higher when input is increased from 0% accuracy of cutoff point: hysteresis: 1% or iess scope of delivery : integrator and mounting bracket mounting: panel flush mounting optional devices : pulse transmitter number of transmission pulses : integral x 1, 2, 5, 10 output contact ; 1a contact (excluding semi-conductor output contact) type of contact ; relay contact contact capacity ac 100v, 0.3a/dc 24v, 0.2a (resistive load) dielectric strength between con- tact and ground : ac 500v for 1 min contactless pulse* output stage of semiconductor contact load current; 50ma or less dielectric strength between po+ and ground ac 500v for 1 min between po+ and po-: dc 33v +0% ?.5% reset pushbutton pulse transmitter pulse transmission input terminal f? v / f 0 to 100hz check terminal = 90 to 60
3 code symbols 12345678 910 description pke 2 allowance 0.5% input signal dc 1 to 5v dc 4 to 20ma code integral v w a b c e 50 100 200 250 300 400 f g j k l m 500 600 750 800 900 1000 n r s t u 1200 1500 1600 1800 2000 code integral code integral integral level integral per hour at 100% input power supply dc 24v ac 100v 50/60hz integration cutoff none cutoff at 10% pulse transmitter pulse width (make time) : 80 to 200ms 1 a b * * * * v u 1 3 0 1 a b c d j k l m y * asterisked (*) items: nonstandard multi- plica- tion 1 2 5 10 relay contact " " " ?contact capacity: dc 24v, 0.2a, dc48v, 0.1a ac 100v, 0.3a, ac 200v, 0.15a ?service life: mechanical 50 million operations, electrical 10 million operations ?dielectric strength: ac 1000v for 1 min between contact and ground type specifications for contact 1 2 5 10 contactless pulse " " " ? ielectric strength between po+ and ground: ac 500v for 1 min between po+ and po-: dc 33v ? oad current: 50ma p0+ p0- none ~
outline diagram (unit : mm) connection diagram pke 1 2 0% 100 pulse output (option) dc 24v (or ac 100v) + - power supply resist- ance input 3 4 5 6 7 8 9 10 11 vp pc i- 1+ 1 0 g c- c+ p 0- p 0+ voltage current check terminal (c-: ground) information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDS10-12E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X